The PV mounting system for all types of pitched roofs

The development of the mounting system TRI-STAND is based on well-founded know-how and years of practical experience. The knowledge gained from the implementation of numerous solar systems resulted in a mounting system that is ideally suited for all applications – from small stand-alone systems to large grid-connected systems, on pitched and flat roofs as well as fronts.

TOIT DE TUILES

Tri Stand Tiles Roof

TÔLE TRAPÉZOÏDALE

Tri Stand Trapezoidal Roof

TOIT PLIÉ EN ACIER

TRI-STAND Système de montage 1

LE FIBROCIMENT ONDULÉ

Tri Stand Corrugated Roof

Les avantages en un coup d’œil

  • Compatible avec les types de modules encadrés

  • Échange simple de modules

  • Profils spéciaux pour une imperméabilité maximale

  • Une surface de module fermée pour des systèmes photovoltaïques esthétiquement attrayants

  • Certificats pour les charges de vent et de neige

  • Testé pour la statique

Profilé rail TS – Le profilé en aluminium

Le profilé rail TS du système de montage TRI-STAND permet le montage aisé, rapide et efficace de tous les panneaux photovoltaïques encadrés courants. Les panneaux sont simplement glissés dans le profil en aluminium, maintenus grâce à la pression de leur poids, sans nécessiter de visseries

Profilés universels UP-L / UP-C+ / UP-LS – Les profilés de base

Les profils universels UP-L et UP-LS sont les profils de base du système de montage TRI-STAND. Le profilé universel UP-L est utilisé pour les systèmes standard, UP-LS pour les crochets de toit avec raccordement latéral. La conception révolutionnaire des profilés universels permet deux types d’installation : le système d’insertion facile à installer avec contreventement transversal et le profilé d’insertion TS ou le système de clip économique avec clips centraux et terminaux. – Le choix vous appartient.

SafeClick SC – Un assemblage sûr

Les SafeClick raccordent de façon sûre et simple les profilés universels des systèmes de montage TRI-STAND à leurs profilés rails. La conception des SafeClick permet un montage aisé par simple clipage des profilés rails, sans besoin de percer.

Le guide central TS-M – Le renforcement optimal

En configuration verticale et pour une charge de pression de plus de 2400 N/m², certains fabricants de panneaux imposent l’emploi d’un appui central. Le guide central TS-M TRI-STAND est parfaitement adapté au système de montage et représente la surface d’appui idéale pour tous les panneaux courants.

Crochets de toit

Pour l’assemblage des sous-structures, les premières fixations doivent être installées à des intervalles appropriés entre les grilles. Sur les toits en tuiles, les crochets de toit sont fixés soit directement sur le chevron, soit à des lattes d’écartement au-dessus du chevron. Les crochets de toit sont disponibles pour presque tous les types de tuiles et sont fixés au moyen de boulons d’assise.

Pinces de pliage de toit

Dans le cas des toits en tôle pliée, les pinces sont installées directement au niveau du pli. Les pinces sont constituées de deux tôles en acier inoxydable, qui sont boulonnées ensemble. Les pinces pour toiture pliante sont disponibles en version ronde, notamment pour les toits Kalzip. La sous-structure peut être montée sur les pinces, sans perturber la surface du toit.

Vis à double filetage

Pour un montage sur toiture en tôle ondulée, les vis existantes sont remplacées par des vis à double filetage. Ces vis servent à la fois à fixer le système de montage et la toiture en tôle ondulée. Le système de montage sera ainsi installée facilement et à peu de frais.

FAQs TRI-STAND

The TS bending tool has two functions. First, it is used with the insertion system and keeps rails from wandering due to heat and cold. To this end, TS profiles are to be bevelled left and right of a SafeClick provided in the middle of the rail. For more information, see the TRI-STAND Installation Instructions. The second function of the bending tool is the removal of a clicked-in TS rail.

Basically, the manufacturer for the insertion system must release all solar modules because not every module is suitable in terms of frames and bearing capacity. In parallel, the modules must also be released by TRITEC since the drainage openings of module frames may not be covered by the TS profile. The certificates of non-objection for the modules in the TRITEC product range are provided in our pv product catalogue.
(Module insertion width + 2mm) x number of modules side by side.
(Module insertion width + 11.5mm) x number of modules on top of each other + 69mm.
For the insertion system, horizontal module mounting is possible without any restrictions – with the corresponding manufacturer’s release. For the clip system, horizontal mounting is possible either in the two-layer clip system or by clipping on the short side of the module. In the latter case, the corresponding manufacturer’s release is also necessary. For more information, see the TRI-STAND Installation Instructions.
Hanger bolts are used to fasten the sub-structure on shingle roofs. These bolts must be centrically set into the counter-battening. Asbestos-containing slates may only be processed if corresponding regulations are complied with. Special hanger bolts are available for the use of TRI-STAND on Eternit cement shingles.
With purlin roofs, the module is horizontally mounted for clip mounting, as a standard. Vertical mounting is possible either in the two-layer clip system or by clipping on the short side of the module. In the latter case, the corresponding manufacturer’s release is necessary. Additionally, be sure to select the correct hanger bolts by taking into account the required minimum dimensions of the fastening timber.
Carefully check the values for wind suction and pressure. Select as many fastening points on the roof as possible since the individual standing seams can accept relatively little load. For the clip system, horizontal mounting of the module is possible either in the two-layer clip system or by clipping on the short side of the module. In the latter case, module release by the manufacturer is necessary.
Measure precisely the module field by means of the drilling jig since the screws of the trapezoidal sheet roof may not collide with the SafeClick rivets. For the insertion system, horizontal module mounting is possible without any restrictions – with the corresponding manufacturer’s release. For the clip system, horizontal mounting is possible either in the two-layer clip system or by clipping on the short side of the module. In the latter case, the corresponding manufacturer’s release is also necessary.

For installations with the insertion system which are wider than 12m, the UP-C connector is tightened only on one side. Make sure that the universal profiles have at least 3mm clearance between them. For installations with the insertion system which are wider than 6m, the TS-C connector is tightened only on one side. Make sure that the TS insertion profiles have at least 3mm clearance between them. With the clip system, the universal profile must end after 12m at the most, and a new installation sections must be started.

Vous avez des questions ?