deutsch | english (UK) | english (global) | franšais | italiano | espa˝ol

Contact

How to contact us:

Give us a callCH  +41 32 665 35 35
Give us a callUK  +41 61 264 00 23

Contact form

TRITEC International

TRITEC UK

All Locations

TRITEC PMT Evolution – Flat roof mounting systems South & East-West

Download

TRITEC PMT (pdf, 1272 kB)
TRITEC PMT Evolution – Flat roof mounting systems South & East-West TRITEC PMT Evolution – Flat roof mounting systems South & East-West

Images

TRITEC PMT flat roof mounting system EVO South
TRITEC PMT flat roof mounting system EVO East-West

Information

The German version is binding. The content is subject to change without prior notice.

TRITEC PMT Evolution – Flat roof mounting systems South & East-West

The TRITEC PMT flat roof system is characterized by the shortest installation time and high stability. The innovative click technology ensures speedy construction, and the short click components facilitate handling during the installation. Additionally, they provide the required measure for the position of the individual components. Time-consuming measurements within the system are thus unnecessary, and errors in construction are prevented since the click connections are matched.
For the entire installation, no sharp small parts are used, such as drilling screws. Also, thanks to no-drill mounting, there will be no sharp metal swarf or filings, which might damage the delicate roof covering. The load transferring composite system of extra-wide support surfaces of the bottom rails, the cube and the base is reinforced by multifunctional cross bracing to maximize the system stability.
Shortest installation time
  • Very small number of components
  • Roof connection without roof penetration
  • Innovative click technology
  • Manageable and handy components for easy and swift handling during installation
  • Even after the system installation, cables may be laid without any additional expenditure
Stability and safety
  • Optimum load distribution and introduction by means of a 150ámm wide support surface of the basic structure on the roof covering
  • Premounted sandwich-type protective building mat (11ámm) fixed to the system to protect the roof covering and to protect against plasticizer migration
  • Unobstructed roof drainage according to DIN 1986-100 by means of partially applied 11-mm thick protective building mat
  • Optimized rear ventilation for maximum energy yield
  • No load transmission via the PV module in longitudinal and/or transverse direction
  • Ballast reduction thanks to aerodynamically optimized construction and the implementation of the latest research findings from system and ballast design software
  • Tested by the independent institute for industrial aerodynamics in the boundary layer wind tunnel according to German and U.S. standards (in compliance with ASCE 7-05, ASCE 7-10 and SEAOC PV 2-2012)
Art. No. 1502900 1502901 1502902
Model TRITEC PMT EVO AEV1BP type 155 TRITEC PMT EVO C10 type 96 TRITEC PMT EVO MK type 80
Scope of applications Grid-connected Stand-alone Grid-connected Stand-alone Grid-connected Stand-alone
Application EVO South & East-West EVO South & East-West EVO South & East-West
Description Start, end and connecting profile type 1 incl. protective building mat Cube 10░ Middle clip 30 ‑ 50 mm
Dimensions (L / W / H) 155 mm / 150 mm / 37.7 mm 190 mm / 96 mm / 205 mm 80 mm / 45 mm / 70 mm
Weight 0.462 kg 0.680 kg 0.066 kg

Art. No. 1502903 1502904 1502905
Model TRITEC PMT EVO EK type 80 TRITEC PMT EVO QBS type 1636 TRITEC PMT EVO BW type 70
Scope of applications Grid-connected Stand-alone Grid-connected Stand-alone Grid-connected Stand-alone
Application EVO South & East-West EVO South & East-West EVO South & East-West
Description End clip 30 – 50 mm Transverse and ballast brace incl. 2 screws M8x35 Ballast trough type 70 incl. 3 protective strips
Dimensions (L / W / H) 80 mm / 35 mm / 70 mm 1636 mm / 25 mm / 39 mm 1752 mm / 800 mm / 76 mm
Weight 0.083 kg 0.840 kg 2.750 kg

Art. No. 1502906 1502907 1502908
Model TRITEC PMT EVO HBP type 1460 TRITEC PMT EVO RW10 TRITEC PMT EVO HBP type 1880
Scope of applications Grid-connected Stand-alone Grid-connected Stand-alone Grid-connected Stand-alone
Application EVO South EVO South EVO East-West
Description Main bottom profile incl. 3 protective building mats & 1 base 10░ Rear wall 10░ Main bottom profile incl. 3 protective building mats & 1 base 10░
Dimensions (L / W / H) 1560 mm / 150 mm / 37.7 (69) mm 1800 mm / 240 mm / 30 mm 1980 mm / 150 mm / 37.7 (69) mm
Weight 3.240 kg 1.340 kg 3.820 kg

Art. No. 1502909 1502910 1502915
Model TRITEC PMT EVO V2BP type 383 TRITEC PMT EVO B10 type 96 TRITEC PMT EVO brace connector type 400
Scope of applications Grid-connected Stand-alone Grid-connected Stand-alone Grid-connected Stand-alone
Application EVO East-West EVO South & East-West EVO South & East-West
Description Connecting bottom profile type 2 incl. protective building mat Base 10░ For transverse and ballast braces
Dimensions (L / W / H) 383 mm / 150 mm / 37.7 mm 162 mm / 96 mm / 56 mm 17 mm / 34 mm / 400 mm
Weight 0.825 kg 0.320 kg 0.240 kg

Art. No. 1502916 1502911 1502914
Model TRITEC PMT EVO brace connector type 1200 TRITEC PMT EVO cable cover type 310 TRITEC PMT EVO cable cover type 530
Scope of applications Grid-connected Stand-alone Grid-connected Stand-alone Grid-connected Stand-alone
Application EVO South & East-West EVO East-West EVO South & East-West
Description For transverse and ballast braces Cable cover for connecting profile type 1 Cable cover for connecting bottom profile type 2
Dimensions (L / W / H) 17 mm / 34 mm / 1200 mm 22 mm / 22 mm / 310 mm 22 mm / 22 mm / 530 mm
Weight 0.720 kg 0.053 kg 0.090 kg