Download

Kaco with transformer (pdf, 125 kB)

Images

Kaco Powador 02 Series
The integrated transformer of the Powador 02 series ensures electrical isolation from the mains, which allows the use of thin-film modules without any problems.
Kaco Powador 02 Series
With an efficiency of 96 %, the inverters of the Kaco Powador 02 series are among the top-rated of their class.

More images

Information

The German version is binding. The content is subject to change without prior notice.

Kaco Powador 02 Series
Great flexibility, simple installation

New current sensor
The new current sensor of the Kaco Powador 02 series enables more precise control and better MPP tracking. The inverters with electrical isolation satisfy with their effortless installation, highest efficiency as well as optimal operation by means of thin-film modules.
Effortless installation
The connections are situated on their own PCB within the casing and can be connected easily. For a faster and easier wiring, all communication connections are mounted separately on a PCB. A DC circuit breaker is integrated into the device.
Highest efficiency
With an efficiency of 96 %, the inverters of the Kaco Powador 02 series are among the top-rated of their class. Due to the electrical isolation, the devices can be installed even in places that would be impossible for devices without transformers. The wide input voltage range makes the devices extremely flexible.
Advantages in brief
  • New current sensor
  • Electrical isolation
  • Simple installation
  • High efficiency
  • Simple wiring
  • Optimal for thin-film modules
  • Display of earthing status of the PV generator
Art. No. 0201124 0201126 0201128
Model Kaco Powador 2002 INT Kaco Powador 3002 INT Kaco Powador 4202 INT
Scope of applications Grid-connected Grid-connected Grid-connected
MPP voltage range 125 ‑ 510 V 200 ‑ 510 V 200 ‑ 510 V
Open circuit voltage 600 V 600 V 600 V
Max. input current 14.3 A 13.5 A 18.5 A
Nominal output 1650 W 2500 W 3500 W
Output voltage 184 ‑ 264 V 184 ‑ 264 V 184 ‑ 264 V
Power factor cos phi 1 1 1
Frequency 50 Hz 50 Hz 50 Hz
Harmonic distortion < 3 % < 3 % < 3 %
Max. efficiency 95.9 % 96.0 % 95.9 %
Euro efficiency 95.3 % 95.4 % 95.1 %
Night-time consumption 0.4 W 0.4 W 0.4 W
Ambient temperature -20 to +60 °C -20 to +60 °C -25 to +60 °C
Heat dissipation Free convection / no fan Free convection / no fan Free convection / no fan
Protection mode IP54 IP54 IP54
Circuit type Self-controlled, electrically isolated, HF transformer Self-controlled, electrically isolated, HF transformer Self-controlled, electrically isolated, HF transformer
DC load disconnector Integrated Integrated Integrated
Grid monitoring Automatic disconnect switch DIN VDE 0126-1-1:2006-02 Automatic disconnect switch DIN VDE 0126-1-1:2006-02 Automatic disconnect switch DIN VDE 0126-1-1:2006-02
Display Two-line LC display, LED Two-line LC display, LED Two-line LC display, LED
Connection PCB clip up to max. 6 mm² PCB clip up to max. 6 mm² PCB clip up to max. 6 mm²
Casing Aluminium Aluminium Aluminium
Dimensions (W / H / D) 450 mm / 340 mm / 200 mm 500 mm / 340 mm / 200 mm 600 mm / 340 mm / 240 mm
Weight 12 kg 20 kg 26 kg
Warranty * 7 years 7 years 7 years
Norms DIN VDE 0126-1-1:2006-02, EN 50178, DIN EN 50178, IEC 62103, RAL seal of approval (RAL GZ 966), G83 DIN VDE 0126-1-1:2006-02, EN 50178, DIN EN 50178, IEC 62103, RAL seal of approval (RAL GZ 966), G83 DIN VDE 0126-1-1:2006-02, EN 50178, DIN EN 50178, IEC 62103, RAL seal of approval (RAL GZ 966), G83

Art. No. 0201130 0201132
Model Kaco Powador 5002 INT Kaco Powador 6002 INT
Scope of applications Grid-connected Grid-connected
MPP voltage range 200 ‑ 510 V 200 ‑ 510 V
Open circuit voltage 600 V 600 V
Max. input current 22.4 A 26.5 A
Nominal output 4200 W 4600 W
Output voltage 184 ‑ 264 V 184 ‑ 264 V
Power factor cos phi 1 1
Frequency 50 Hz 50 Hz
Harmonic distortion < 3 % < 3 %
Max. efficiency 95.9 % 95.9 %
Euro efficiency 95.3 % 95.3 %
Night-time consumption 0.4 W 0.4 W
Ambient temperature -25 to +60 °C -25 to +60 °C
Heat dissipation Fan Fan
Protection mode IP54 IP54
Circuit type Self-controlled, electrically isolated, HF transformer Self-controlled, electrically isolated, HF transformer
DC load disconnector Integrated Integrated
Grid monitoring Automatic disconnect switch DIN VDE 0126-1-1:2006-02 Automatic disconnect switch DIN VDE 0126-1-1:2006-02
Display Two-line LC display, LED Two-line LC display, LED
Connection PCB clip up to max. 6 mm² PCB clip up to max. 6 mm²
Casing Aluminium Aluminium
Dimensions (W / H / D) 600 mm / 340 mm / 240 mm 600 mm / 340 mm / 240 mm
Weight 28 kg 28 kg
Warranty * 7 years 7 years
Norms DIN VDE 0126-1-1:2006-02, EN 50178, DIN EN 50178, IEC 62103, RAL seal of approval (RAL GZ 966), G83 DIN VDE 0126-1-1:2006-02, EN 50178, DIN EN 50178, IEC 62103, RAL seal of approval (RAL GZ 966), G83


* ‑ Can optionally be extended to 10 / 15 / 20 / 25 years