| Model |
Danfoss ULX 1800 MV (outdoor) |
Danfoss ULX 1800 HV (outdoor) |
Danfoss ULX 3000 MV (outdoor) |
| Scope of applications |
|
|
|
| Max. recommended PV system power |
1950 W |
1950 W |
3200 W |
| Max. DC output |
1950 W |
1950 W |
3200 W |
| Max. input current |
10 A |
7 A |
2 x 10 A |
| Max. input voltage * |
450 / 410 V |
600 / 550 V |
450 / 410 V |
| MPPT range |
180 ‑ 350 V |
260 ‑ 500 V |
180 ‑ 350 V |
| Operation modes |
One MPP tracker |
One MPP tracker |
Two independent MPP trackers or Master-Slave with one MPP tracker |
| Independent MPPT trackers |
1 pc. |
1 pc. |
2 pc. |
| Max. output power |
1800 W |
1800 W |
3000 W |
| Nominal output power |
1650 W |
1650 W |
2750 W |
| Output voltage |
230 V ±0.15 % |
230 V ±0.15 % |
230 V ±0.15 % |
| Max. output current |
8.0 A |
8.0 A |
13.0 A |
| Nominal output current |
7.2 A |
7.2 A |
12.0 A |
| Start-up power level |
20 W |
20 W |
20 W |
| Stand-by power consumption |
8 W |
8 W |
8 W |
| Max. efficiency |
93.7 % |
93.7 % |
94.2 % |
| Euro efficiency |
91.6 % |
91.6 % |
92.9 % |
| Operating temperature |
-25 to +60 °C |
-25 to +60 °C |
-25 to +60 °C |
| Rel. humidity |
0 ‑ 95 % |
0 ‑ 95 % |
0 ‑ 95 % |
| Protection mode |
IP54 |
IP54 |
IP54 |
| Circuit type |
High frequency transformer, single-phased |
High frequency transformer, single-phased |
High frequency transformer, single-phased |
| Power factor (P > 20 %) |
0.97 |
0.97 |
0.97 |
| Harmonic distortion |
< 5 % |
< 5 % |
< 5 % |
| Galvanic safety class |
Class I |
Class I |
Class I |
| Surge protection AC + DC |
Integrated |
Integrated |
Integrated |
| DC load disconnector |
Integrated |
Integrated |
Integrated |
| Reverse-polarity protection |
Integrated |
Integrated |
Integrated |
| Data communication |
RS485 interface, for the connection of optional datalogger |
RS485 interface, for the connection of optional datalogger |
RS485 interface, for the connection of optional datalogger |
| Connection |
MC-PV4 |
MC-PV4 |
MC-PV4 |
| Dimensions (W / H / D) ** |
489 mm / 434 mm / 192 mm |
489 mm / 434 mm / 192 mm |
618 mm / 434 mm / 192 mm |
| Weight |
17 kg |
17 kg |
20 kg |
| Warranty *** |
5 years |
5 years |
5 years |
| Norms |
73/23/EC, 2004/108/EC, EN 50178, EN 61000-6-1, EN 61000-6-2, EN 61000-4-13-14-28, EN 60146-1, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2-3, DIN VDE 0126-1-1, IEC 61727, EN 50160 |
73/23/EC, 2004/108/EC, EN 50178, EN 61000-6-1, EN 61000-6-2, EN 61000-4-13-14-28, EN 60146-1, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2-3, DIN VDE 0126-1-1, IEC 61727, EN 50160 |
73/23/EC, 2004/108/EC, EN 50178, EN 61000-6-1, EN 61000-6-2, EN 61000-4-13-14-28, EN 60146-1, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2-3, DIN VDE 0126-1-1, IEC 61727, EN 50160 |
|
 |
 |
 |
| Model |
Danfoss ULX 3000 HV (outdoor) |
Danfoss ULX 3600 MV (outdoor) |
Danfoss ULX 3600 HV (outdoor) |
| Scope of applications |
|
|
|
| Max. recommended PV system power |
3200 W |
3900 W |
3900 W |
| Max. DC output |
3200 W |
3900 W |
3900 W |
| Max. input current |
2 x 7 A |
2 x 10 A |
2 x 7 A |
| Max. input voltage * |
600 / 550 V |
450 / 410 V |
600 / 550 V |
| MPPT range |
260 ‑ 500 V |
180 ‑ 350 V |
260 ‑ 500 V |
| Operation modes |
Two independent MPP trackers or Master-Slave with one MPP tracker |
Two independent MPP trackers or Master-Slave with one MPP tracker |
Two independent MPP trackers or Master-Slave with one MPP tracker |
| Independent MPPT trackers |
2 pc. |
2 pc. |
2 pc. |
| Max. output power |
3000 W |
3600 W |
3600 W |
| Nominal output power |
2750 W |
3300 W |
3300 W |
| Output voltage |
230 V ±0.15 % |
230 V ±0.15 % |
230 V ±0.15 % |
| Max. output current |
13.0 A |
15.5 A |
15.5 A |
| Nominal output current |
12.0 A |
14.5 A |
14.5 A |
| Start-up power level |
20 W |
20 W |
20 W |
| Stand-by power consumption |
8 W |
8 W |
8 W |
| Max. efficiency |
94.2 % |
94.2 % |
94.2 % |
| Euro efficiency |
92.9 % |
93.4 % |
93.4 % |
| Operating temperature |
-25 to +60 °C |
-25 to +60 °C |
-25 to +60 °C |
| Rel. humidity |
0 ‑ 95 % |
0 ‑ 95 % |
0 ‑ 95 % |
| Protection mode |
IP54 |
IP54 |
IP54 |
| Circuit type |
High frequency transformer, single-phased |
High frequency transformer, single-phased |
High frequency transformer, single-phased |
| Power factor (P > 20 %) |
0.97 |
0.97 |
0.97 |
| Harmonic distortion |
< 5 % |
< 5 % |
< 5 % |
| Galvanic safety class |
Class I |
Class I |
Class I |
| Surge protection AC + DC |
Integrated |
Integrated |
Integrated |
| DC load disconnector |
Integrated |
Integrated |
Integrated |
| Reverse-polarity protection |
Integrated |
Integrated |
Integrated |
| Data communication |
RS485 interface, for the connection of optional datalogger |
RS485 interface, for the connection of optional datalogger |
RS485 interface, for the connection of optional datalogger |
| Connection |
MC-PV4 |
MC-PV4 |
MC-PV4 |
| Dimensions (W / H / D) ** |
618 mm / 434 mm / 192 mm |
618 mm / 434 mm / 192 mm |
618 mm / 434 mm / 192 mm |
| Weight |
20 kg |
20 kg |
20 kg |
| Warranty *** |
5 years |
5 years |
5 years |
| Norms |
73/23/EC, 2004/108/EC, EN 50178, EN 61000-6-1, EN 61000-6-2, EN 61000-4-13-14-28, EN 60146-1, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2-3, DIN VDE 0126-1-1, IEC 61727, EN 50160 |
73/23/EC, 2004/108/EC, EN 50178, EN 61000-6-1, EN 61000-6-2, EN 61000-4-13-14-28, EN 60146-1, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2-3, DIN VDE 0126-1-1, IEC 61727, EN 50160 |
73/23/EC, 2004/108/EC, EN 50178, EN 61000-6-1, EN 61000-6-2, EN 61000-4-13-14-28, EN 60146-1, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2-3, DIN VDE 0126-1-1, IEC 61727, EN 50160 |
|
 |
 |
| Model |
Danfoss ULX 5400 MV (outdoor) |
Danfoss ULX 5400 HV (outdoor) |
| Scope of applications |
|
|
| Max. recommended PV system power |
5400 W |
5400 W |
| Max. DC output |
5850 W |
5850 W |
| Max. input current |
3 x 10 A |
3 x 7 A |
| Max. input voltage * |
450 / 410 V |
600 / 550 V |
| MPPT range |
180 ‑ 350 V |
260 ‑ 500 V |
| Operation modes |
Three independent MPP trackers or Master-Slave with one MPP tracker |
Three independent MPP trackers or Master-Slave with one MPP tracker |
| Independent MPPT trackers |
3 pc. |
3 pc. |
| Max. output power |
5000 / 5400 W |
5000 / 5400 W |
| Nominal output power |
4600 W |
4600 W |
| Output voltage |
230 V ±0.15 % |
230 V ±0.15 % |
| Max. output current |
23.0 A |
23.0 A |
| Nominal output current |
20.0 A |
20.0 A |
| Start-up power level |
20 W |
20 W |
| Stand-by power consumption |
8 W |
8 W |
| Max. efficiency |
94.3 % |
94.3 % |
| Euro efficiency |
93.4 % |
93.4 % |
| Operating temperature |
-25 to +60 °C |
-25 to +60 °C |
| Rel. humidity |
0 ‑ 95 % |
0 ‑ 95 % |
| Protection mode |
IP54 |
IP54 |
| Circuit type |
High frequency transformer, single-phased |
High frequency transformer, single-phased |
| Power factor (P > 20 %) |
0.97 |
0.97 |
| Harmonic distortion |
< 5 % |
< 5 % |
| Galvanic safety class |
Class I |
Class I |
| Surge protection AC + DC |
Integrated |
Integrated |
| DC load disconnector |
Integrated |
Integrated |
| Reverse-polarity protection |
Integrated |
Integrated |
| Data communication |
RS485 interface, for the connection of optional datalogger |
RS485 interface, for the connection of optional datalogger |
| Connection |
MC-PV4 |
MC-PV4 |
| Dimensions (W / H / D) ** |
747 mm / 434 mm / 192 mm |
747 mm / 434 mm / 192 mm |
| Weight |
23 kg |
23 kg |
| Warranty *** |
5 years |
5 years |
| Norms |
73/23/EC, 2004/108/EC, EN 50178, EN 61000-6-1, EN 61000-6-2, EN 61000-4-13-14-28, EN 60146-1, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2-3, DIN VDE 0126-1-1, IEC 61727, EN 50160 |
73/23/EC, 2004/108/EC, EN 50178, EN 61000-6-1, EN 61000-6-2, EN 61000-4-13-14-28, EN 60146-1, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2-3, DIN VDE 0126-1-1, IEC 61727, EN 50160 |
|