Download

Danfoss TripleLynx (pdf, 208 kB)

Images

Danfoss TripleLynx – The most versatile inverter on the market
The transformerless Danfoss TripleLynx inverter series with three-phase power supply and a sensational effectiveness of 98 %.
Danfoss TripleLynx – The most versatile inverter on the market
The TripleLynx inverters are optionally available as the Plus model (incl. reactive power compensation) and the Pro model (incl. web server).

More images

Documents

Press Release Grid Integration (German) (pdf, 35 kB)
Installation Manual (pdf, 3125 kB)
User Manual (pdf, 5262 kB)
Reference Manual (pdf, 3079 kB)
Declaration of Conformity (pdf, 171 kB)
Country Settings (pdf, 283 kB)
VDE Certificate of Compliance (pdf, 556 kB)
RCMU Declaration (pdf, 147 kB)
Declaration Plants Greater than 30 kVA (pdf, 160 kB)
Harmonic Analysis (pdf, 226 kB)

Information

The German version is binding. The content is subject to change without prior notice.

Danfoss TripleLynx – The most versatile inverter on the market

The three-phase Danfoss TripleLynx inverters are available with outputs of 6, 8, 10, 12.5 and 15 kW and are suitable for outdoor use, weighing a mere 35 kg. Due to their ease-of-use, geared to economic applications, and their wide range of operating specifications, these inverters are the most versatile on the market.
It's all there – wide range of operating specifications
The inverter has two or three independent string inputs, an extensive operating field, and a three-phase output, which makes it incredibly versatile. Thanks to its wide range of operating specifications, the inverter can be connected to a variety of modules each with different string configurations.
High output due to effective MPP trackers and high efficiency
Three individual MPP controllers always ensure an optimal output of the system, irrespective of the differences in size or the location of the PV modules. The accuracy of the MPP controllers was verified by the Viennese Arsenal Research Institute, measuring an efficiency of 99.9 % of the MPP controller. With an effectiveness of 98 %, this inverter positions itself at the top of the three-phase devices on the market.
Three-phase grid connection
A perfectly symmetrical three-phase power supply requires nothing more than an inverter. A three-phase inverter ensures three-phase output at all times as well as compliance with the rules for grid connection irrespective of string fluctuations on the input side.
Features and innovations
  • Up to three independent power inputs
  • Preprogrammed for 16 countries
  • Integrated communication board
  • Communication with RS­485 and integrated modem
  • Alarm display for faults
  • Integrated DC switch
  • Integrated cable lock
  • Integrated insulation monitoring
  • Separate connection compartment
  • Service tool for ultra-easy maintenance
Art. No. 0201598 0201599 0201512
Model Danfoss TLX 6k + Danfoss TLX 6k Pro + Danfoss TLX 8k +
Scope of applications Grid-connected Grid-connected Grid-connected
Max. recommended PV system power 7100 W 7100 W 9500 W
Max. DC output 6200 W 6200 W 8240 W
Max. input current 2 x 12 (24) A 2 x 12 (24) A 2 x 12 (24) A
Max. input voltage 1000 V 1000 V 1000 V
MPPT range 260 ‑ 800 V 260 ‑ 800 V 345 ‑ 800 V
Independent MPPT trackers 2 pc. 2 pc. 2 pc.
Max. output power 6000 W 6000 W 8000 W
Nominal output power 6000 W 6000 W 8000 W
Output voltage 3 x 230 V ±20 % 3 x 230 V ±20 % 3 x 230 V ±20 %
Max. output current 3 x 9.0 A 3 x 9.0 A 3 x 12.0 A
Start-up power level 20 W 20 W 20 W
Stand-by power consumption < 5 W < 5 W < 5 W
Max. efficiency 97.8 % 97.8 % 97.9 %
Euro efficiency 96.5 % 96.5 % 97 %
Operating temperature -25 to +60 °C -25 to +60 °C -25 to +60 °C
Rel. humidity 0 ‑ 95 % non condensing 0 ‑ 95 % non condensing 0 ‑ 95 % non condensing
Protection mode IP54 IP54 IP54
Circuit type Transformerless, three-phased Transformerless, three-phased Transformerless, three-phased
Power factor (P > 20 %) 0.97 0.97 0.97
Harmonic distortion < 4 % < 4 % < 4 %
Galvanic safety class Class I Class I Class I
Surge protection AC + DC Integrated Integrated Integrated
DC load disconnector Integrated Integrated Integrated
Reverse-polarity protection Integrated Integrated Integrated
Data communication RS­485 interface, Power Level Adjustment, sensor inputs, optional: GSM modem, web logger RS­485 interface, Power Level Adjustment, sensor inputs, optional: GSM modem, web logger RS­485 interface, Power Level Adjustment, sensor inputs, optional: GSM modem, web logger
Reactive power Reactive power setting protection in display unit Reactive power setting protection in display unit Reactive power setting protection in display unit
Ethernet - Ethernet serial and Star, software update from master, allocation of settings from master, web server -
Connection MC-PV4 MC-PV4 MC-PV4
Dimensions (W / H / D) 700 mm / 525 mm / 250 mm 700 mm / 525 mm / 250 mm 700 mm / 525 mm / 250 mm
Weight 35 kg 35 kg 35 kg
Warranty * 5 years 5 years 5 years
Norms 2006/95/EC, 2004/108/EC, EN 50178, EN 61000-6-1, EN61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2/-3, DIN VDE 0126-1-1, IEC 61727, EN 50160, G83 2006/95/EC, 2004/108/EC, EN 50178, EN 61000-6-1, EN61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2/-3, DIN VDE 0126-1-1, IEC 61727, EN 50160, G83 2006/95/EC, 2004/108/EC, EN 50178, EN 61000-6-1, EN61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2/-3, DIN VDE 0126-1-1, IEC 61727, EN 50160, G83

Art. No. 0201513 0201205 0201211
Model Danfoss TLX 8k Pro + Danfoss TLX 10k + Danfoss TLX 10k Pro +
Scope of applications Grid-connected Grid-connected Grid-connected
Max. recommended PV system power 9500 W 11800 W 11800 W
Max. DC output 8240 W 10300 W 10300 W
Max. input current 2 x 12 (24) A 2 x 12 (24) A 2 x 12 (24) A
Max. input voltage 1000 V 1000 V 1000 V
MPPT range 345 ‑ 800 V 430 ‑ 800 V 430 ‑ 800 V
Independent MPPT trackers 2 pc. 2 pc. 2 pc.
Max. output power 8000 W 10000 W 10000 W
Nominal output power 8000 W 10000 W 10000 W
Output voltage 3 x 230 V ±20 % 3 x 230 V ±20 % 3 x 230 V ±20 %
Max. output current 3 x 12.0 A 3 x 15.0 A 3 x 15.0 A
Start-up power level 20 W 20 W 20 W
Stand-by power consumption < 5 W < 5 W < 5 W
Max. efficiency 97.9 % 98.0 % 98.0 %
Euro efficiency 97 % > 97 % > 97 %
Operating temperature -25 to +60 °C -25 to +60 °C -25 to +60 °C
Rel. humidity 0 ‑ 95 % non condensing 0 ‑ 95 % non condensing 0 ‑ 95 % non condensing
Protection mode IP54 IP54 IP54
Circuit type Transformerless, three-phased Transformerless, three-phased Transformerless, three-phased
Power factor (P > 20 %) 0.97 0.97 0.97
Harmonic distortion < 4 % < 5 % < 5 %
Galvanic safety class Class I Class I Class I
Surge protection AC + DC Integrated Integrated Integrated
DC load disconnector Integrated Integrated Integrated
Reverse-polarity protection Integrated Integrated Integrated
Data communication RS­485 interface, Power Level Adjustment, sensor inputs, optional: GSM modem, web logger RS­485 interface, Power Level Adjustment, sensor inputs, optional: GSM modem, web logger RS­485 interface, Power Level Adjustment, sensor inputs, optional: GSM modem, web logger
Reactive power Reactive power setting protection in display unit Reactive power setting protection in display unit Reactive power setting protection in display unit
Ethernet Ethernet serial and Star, software update from master, allocation of settings from master, web server - Ethernet serial and Star, software update from master, allocation of settings from master, web server
Connection MC-PV4 MC-PV4 MC-PV4
Dimensions (W / H / D) 700 mm / 525 mm / 250 mm 700 mm / 525 mm / 250 mm 700 mm / 525 mm / 250 mm
Weight 35 kg 35 kg 35 kg
Warranty * 5 years 5 years 5 years
Norms 2006/95/EC, 2004/108/EC, EN 50178, EN 61000-6-1, EN61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2/-3, DIN VDE 0126-1-1, IEC 61727, EN 50160, G83 2006/95/EC, 2004/108/EC, EN 50178, EN 61000-6-1, EN61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2/-3, DIN VDE 0126-1-1, IEC 61727, EN 50160, G83 2006/95/EC, 2004/108/EC, EN 50178, EN 61000-6-1, EN61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2/-3, DIN VDE 0126-1-1, IEC 61727, EN 50160, G83

Art. No. 0201206 0201212 0201207
Model Danfoss TLX 12.5k + Danfoss TLX 12.5k Pro + Danfoss TLX 15k +
Scope of applications Grid-connected Grid-connected Grid-connected
Max. recommended PV system power 14700 W 14700 W 17700 W
Max. DC output 12900 W 12900 W 15500 W
Max. input current 3 x 12 (36) A 3 x 12 (36) A 3 x 12 (36) A
Max. input voltage 1000 V 1000 V 1000 V
MPPT range 430 ‑ 800 V 430 ‑ 800 V 430 ‑ 800 V
Independent MPPT trackers 3 pc. 3 pc. 3 pc.
Max. output power 12500 W 12500 W 15000 W
Nominal output power 12500 W 12500 W 15000 W
Output voltage 3 x 230 V ±20 % 3 x 230 V ±20 % 3 x 230 V ±20 %
Max. output current 3 x 19.0 A 3 x 19.0 A 3 x 22.0 A
Start-up power level 20 W 20 W 20 W
Stand-by power consumption < 5 W < 5 W < 5 W
Max. efficiency 98.0 % 98.0 % 98.0 %
Euro efficiency > 97 % > 97 % > 97 %
Operating temperature -25 to +60 °C -25 to +60 °C -25 to +60 °C
Rel. humidity 0 ‑ 95 % non condensing 0 ‑ 95 % non condensing 0 ‑ 95 % non condensing
Protection mode IP54 IP54 IP54
Circuit type Transformerless, three-phased Transformerless, three-phased Transformerless, three-phased
Power factor (P > 20 %) 0.97 0.97 0.97
Harmonic distortion < 5 % < 5 % < 5 %
Galvanic safety class Class I Class I Class I
Surge protection AC + DC Integrated Integrated Integrated
DC load disconnector Integrated Integrated Integrated
Reverse-polarity protection Integrated Integrated Integrated
Data communication RS­485 interface, Power Level Adjustment, sensor inputs, optional: GSM modem, web logger RS­485 interface, Power Level Adjustment, sensor inputs, optional: GSM modem, web logger RS­485 interface, Power Level Adjustment, sensor inputs, optional: GSM modem, web logger
Reactive power Reactive power setting protection in display unit Reactive power setting protection in display unit Reactive power setting protection in display unit
Ethernet - Ethernet serial and Star, software update from master, allocation of settings from master, web server -
Connection MC-PV4 MC-PV4 MC-PV4
Dimensions (W / H / D) 700 mm / 525 mm / 250 mm 700 mm / 525 mm / 250 mm 700 mm / 525 mm / 250 mm
Weight 35 kg 35 kg 35 kg
Warranty * 5 years 5 years 5 years
Norms 2006/95/EC, 2004/108/EC, EN 50178, EN 61000-6-1, EN61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2/-3, DIN VDE 0126-1-1, IEC 61727, EN 50160, G83 2006/95/EC, 2004/108/EC, EN 50178, EN 61000-6-1, EN61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2/-3, DIN VDE 0126-1-1, IEC 61727, EN 50160, G83 2006/95/EC, 2004/108/EC, EN 50178, EN 61000-6-1, EN61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2/-3, DIN VDE 0126-1-1, IEC 61727, EN 50160, G83

Art. No. 0201213
Model Danfoss TLX 15k Pro +
Scope of applications Grid-connected
Max. recommended PV system power 17700 W
Max. DC output 15500 W
Max. input current 3 x 12 (36) A
Max. input voltage 1000 V
MPPT range 430 ‑ 800 V
Independent MPPT trackers 3 pc.
Max. output power 15000 W
Nominal output power 15000 W
Output voltage 3 x 230 V ±20 %
Max. output current 3 x 22.0 A
Start-up power level 20 W
Stand-by power consumption < 5 W
Max. efficiency 98.0 %
Euro efficiency > 97 %
Operating temperature -25 to +60 °C
Rel. humidity 0 ‑ 95 % non condensing
Protection mode IP54
Circuit type Transformerless, three-phased
Power factor (P > 20 %) 0.97
Harmonic distortion < 5 %
Galvanic safety class Class I
Surge protection AC + DC Integrated
DC load disconnector Integrated
Reverse-polarity protection Integrated
Data communication RS­485 interface, Power Level Adjustment, sensor inputs, optional: GSM modem, web logger
Reactive power Reactive power setting protection in display unit
Ethernet Ethernet serial and Star, software update from master, allocation of settings from master, web server
Connection MC-PV4
Dimensions (W / H / D) 700 mm / 525 mm / 250 mm
Weight 35 kg
Warranty * 5 years
Norms 2006/95/EC, 2004/108/EC, EN 50178, EN 61000-6-1, EN61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2/-3, DIN VDE 0126-1-1, IEC 61727, EN 50160, G83


* ‑ Can optionally be extended to 10 years